Description
The
PR-243 incorporates sophisticated integrated circuits and
a 100% solid state piezoresistive silicon sensor to not
only provide a high-level, fully-conditioned and temperature compensated
output, but also to offer up to three (3) field selectable
pressure ranges in one unit. The field selectable feature
eliminates
costly inefficiencies by providing a single
unit which can be configured to cover all the pressure
ranges for a particular
application. For instance, 5, 10 and 20 psig in one unit.
Two industry standard output versions are available, 4-20mA 2-wire loop or field selectable 0-5 VDC/0-10
VDC. Wide 12-40 VDC or 12-35 VAC unregulated
supply voltage and a broad 0°F-180°F compensated
temperature range ensures compatibility to most of the applications. Rugged NEMA-4 (IP-65) enclosure, gasketed cover, external mounting bracket,
fully temperature compensated NIST traceable accuracy and
a liberal five year warranty are some of the features which
make the PR-243 the industry’s
most reliable, rugged, and economical pressure sensor.
The
PR-243 sensing element is a 100% solid state piezoresistive
silicon chip featuring low hysteresis, excellent repeatability,
and long term stability. The chip is connected as a four-active-element
bridge circuit for optimum linearity and sensitivity. Signal
conditioning and temperature compensation are performed
by industrial
quality, state-of-the-art integrated circuits
to provide an accurate, linear, and high level output that
requires no additional signal conditioning.
The PR-243
incorporates sophisticated integrated circuits to not only
provide a high level, fully conditioned and temperature compensated
output, but also to offer field selectable flexibility
which was unheard of in the industry. The
PR-243 offers up to three field selectable pressure ranges
in one unit. In this way, a customer does not need to know
the exact pressure range prior to selection. A unit can
be field configured for the desired pressure range in the
field. With fixed range units, in case of engineering error
or incorrect selection, the only solution is expensive
field recalibration or time consuming product exchange
or replacement. Similarly, numerous units have to be kept
in stock as spares to cover all ranges in case of field
failure. The PR-243 with the field selectable pressure
range feature, eliminates above mentioned costly inefficiencies.
A single unit can be configured to cover all the pressure
ranges in a particular application thereby eliminating
any possibility of incorrect range selection. Additionally,
one unit can be kept in stock and, in the event of a failure,
it can be field configured thereby eliminating the need to
stock numerous fixed range units. (For a complete listing of all the ranges available, please see the ordering information section on page three.)
On
VDC output units, two additional field selectable options
are available: dual outputs 0-5 or 0-10 VDC, and dual
unregulated supply voltages 12-35 VAC or 12-40 VDC.
By merely setting a dip switch, one can select the desired output for
the specific application. As far as supply voltage is concerned,
the unit automatically configures for AC or DC and no field
selection is necessary. Another feature is that the output
is fully protected from short circuit to ground, or if
the supply voltage is applied by mistake to the output.
Past experience demonstrates that field related wiring
problems do occur. Instead of denying this fact, the protection
circuit is designed in to ensure trouble-free start up.
The VDC
output unit is also designed to handle low impedance
circuits. In fact, the unit can drive up to 1K ohms minimum.
In this way, multiple controllers, indicators, or other
devices can be paralleled to the output without performance degradation.
The
mA output units can function over a wide unregulated supply
voltage range: 12-40 VDC without any effect on calibration
or performance. The unit has reverse polarity protection
built in. As a result, it is next to impossible to damage
the unit by mis-wiring. By using sophisticated low drop-out
voltage regulators and CMOS integrated circuits, the mA
output
unit can drive very high output impedance. In fact,
with only 12 VDC supply, the unit can drive 400 ohms. At
40 VDC, the unit is capable of handling up to a 3000 ohms
load. In this way, the output loop can be tied in series
to multiple controllers, indicators, and other devices without
degrading the performance.
The
PR-243 incorporates a rugged NEMA 4 (IP-65) fully gasketed,
dust proof and splash proof enclosure. The enclosure has
an external mounting bracket to facilitate field installation.
A ½" (.875"/22.25 mm diameter) knock-out
for conduit connection is also provided. A liquid tight
cable
connector is also supplied if the unit is not being hard
wired. Once installed, the enclosure maintains its rating and protects the electronics and the sensing element
from
condensation, corrosive contaminants and other environmental
pollutants. The unit also has additional features for ease
of installation including unpluggable terminal block, easily
accessible zero and span trimmers, and conveniently located